BMYTC - VACUUM PUMP OIL

  • MSDS: BMYTC
  • Manufacturer: MOBIL OIL CORP
  • Product Name: VACUUM PUMP OIL
  • National Stock Number: 9150-00N029179
Product Identification

Product ID:VACUUM PUMP OIL
MSDS Date:06/10/1991
FSC:9150
NIIN:00N029179
MSDS Number: BMYTC

Responsible Party
MOBIL OIL CORP
3225 GALLOWS RD
FAIRFAX, VA 22037
US

Emergency Phone: 609-737-4411;800-424-9300(CHEMTREC)

Info Phone: 800-662-4525;800-227-0707

Preparer: ENVIRON HLTH & SFTY DEPT

Cage: 1E969

Contractor
MOBIL OIL CORP ENVIRONMENTAL AFFAIRS & TOXICOLOGY
PENNINGTON, NJ 08534 US

Telephone: 703-849-3265

Cage: 0AHK0

Ingredients

BASE OILS CONTAINING INGRED 2 AND 3.

RTECS: 9999999ZZ


MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-DEWAXED HEAVY

CAS: 64742-65-0

RTECS: PY8038500

OSHA PEL 5 MG/M3(OIL MIST)MFR

ACGIH TLV: 5 MG/M3;10STEL(MIST)


MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-REFINED MILD

CAS: 64741-88-4

RTECS: PY8040500

OSHA PEL 5 MG/M3 (MFR)

ACGIH TLV: 5MG/M3;10 STEL(MFR)


CONSIDERATION OF PRODUCT CHARACTERISTICS AT TIME

RTECS: 9999999ZZ


US COAST GUARD REGULATIONS REQUIRE IMMED

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50: (ORAL,RAT) > 15 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHAL: HARMFUL CONC OF MISTS &/OR VAPS
ARE UNLIKELY TO BE ENCOUNTERED THRU ANY CUSTOMARY/REASONABLY
FORESEEABLE HNDLG, USE, OR MISUSE OF THIS PROD. EYE/SKIN: EXPECTED
TO BE NON-IRRIT. BASED ON TESTING OF SIMILAR PRODUCTS AND/OR THE
COMPONENTS.
Explanation of Carcinogenicity:CAS #64742-65-0 AND 64741-88-4 ARE
LISTED BY RTECS AS IARC GROUP 1 CARCIN
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE: IMMED FLUSH WITH POTABLE WATER FOR A MINIMUM OF 15 MIN.
SEEK ASSISTANCE FROM MD . SKIN: FLUSH WITH COPIOUS AMOUNTS OF
WATER. CALL MD . INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (G
IVE O2/ARTF RESP) . INGEST: GET MD IMMEDIATELY .

Fire Fighting

Flash Point Method:COC
Flash Point:>400F,>204C
Lower Limits:0.6 %
Upper Limits:7 %
Extinguishing Media:CO2, FOAM, DRY CHEMICAL AND WATER FOG.
Fire Fighting Procedures:H2O/FOAM MAY CAUSE FROTHING. USE H2O TO KEEP
FIRE EXPOS CNTNRS COOL. H2O SPRAY MAY BE USED TO FLUSH SPILLS AWAY
FROM EXPOS. FOR FIRES IN ENCLOSED (SUPP DATA)
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:ABSORB ON FIRE RETARDANT TREATED SAWDUST,
DIATOMACEOUS EARTH, ETC. SHOVEL UP AND DISPOSE OF AT AN APPROPRIATE
WASTE DISPOSAL FACILITY IN ACCORDANCE WITH CURRENT APPLICABLE LAWS
AND REGULATIONS, AND PR ODUCT CHARACTERISTICS AT TIME OF DISPOSAL.
(ING 5)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NO SPECIAL PRECAUTIONS REQUIRED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:NO SPECIAL REQUIREMENTS UNDER ORDINARY CONDITIONS OF USE
AND WITH ADEQUATE VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:GOOD PERSONAL HYGIENE PRACTICES SHOULD ALWAYS
BE FOLLOWED.
Supplemental Safety and Health
FIRE FIGHT PROC: AREAS. FIRE FIGHTERS MUST WEAR NIOSH/MSHA APPRVD SCBA
& FULL PROT EQUIP . PVNT RUNOFF FROM FIRE CONTROL/DILUTION FROM
ENTERING STREAMS, SEWERS/DRINKING H2O SUPPLY. WASTE DISP ME TH:
FACILITY. USE OF THESE METHODS IS SUBJECT TO USER COMPLIANCE W/
APPLIC FED, STATE & LOC LAWS & REGS AND (ING 4)

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:>600F,>316C
Vapor Pres:< 0.1
Spec Gravity:0.876
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER LIQUID. MILD ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:STRONG OXIDATION.
Hazardous Decomposition Products:CARBON MONOXIDE.

Disposal

Waste Disposal Methods:PROD IS SUITABLE FOR BURNING IN AN ENCLOSED,
CONTROLLED, BURNER FOR FUEL VALUE/DISPOSAL BY SUPERVISED
INCINERATION. SUCH BURNING MAY BE LIMITED PERSUANT TO RCRA. IN
ADDITION, THE PROD IS SUITABLE FOR PROCESSING BY AN APPROVED WASTE
DISP (SUPP DATA)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.